| Chinese Version | Dcco Home Page | Dept Page | Last Page |

SIMOSA Oil CO., LTD.

| Brief | Product | Location | Sales Area | Contact us |


Penetration grades 80/100
  

No. Test Item Test Methods Spec. Unit
1 Flash point and Fire point ASTM D92 ¡Ö232 ¢J
2 Penetration 25¢J ASTM D5 80-100 mm/10
3 Softening point ASTM D36 42-52 ¢J
4 Specific gravity at 25¢J/25¢J ASTM D70 1.00-1.05 NIL
5 Ductility at 25¢J ASTM D113 ¡Ö130 cm
6 Ductility at 15¢J ASTM D113 ¡Ö100 cm
7 Solubility in C2HCl3 ASTM D2042 ¡Ö99.5 wt %
8 Viscosity at 60¢J ASTM D2171 Report Poise
9 Viscosity at 135¢J ASTM D2170 Report cSt
10 Wax Content DIN 52015 ¡Õ2.0 %
11 TFOT
Loss on heating ASTM 
D1754/D6
¡Õ0.5 wt %
Penetration of residue,% of Original ASTM
D1754/D5 
¡Ö50 %
Ductility of residue at 25¢J ASTM 
D1754/D113
¡Ö100 cm
Ductility of residue at 15¢J ASTM 
D1754/D113
Report cm
Viscosity of residue 60¢J ASTM
D1754/D2171
Report Poise

Copyright DCCO  All rights reserved. | Dcco Home Page | Dept Page | Last Page |